Witham Logo Click To Go Homepage Witham Fourth District Internal Drainage Board
   | Home | Contact | Organisation | Accounts | Consent Forms | History | Vacancies | Sale Items |Links|
WITHAM FOURTH DISTRICT INTERNAL DRAINAGE BOARD

Pumping Stations


 

Lade Bank Pumping Station

Lade Bank

 

Lade Bank Pumping Station built in 1937 with an old cooling system. This was replaced with a new cooling system during the Summer of 2005.

 

crane

cheer

 

 

 

 

 

 

 

 

For pumping information please go to the pump status link.

 

Pumping Station Statistics:

No. Of Pumps

Size (dia.)

Type

Power

Total Capacity

Catchment Area

3

50"

Axial Flow

240hp

602 cusers

30,800ac

2

800mm

Submersible

110kw

(17 cumecs)

(12,467ha)

1

36"

Axial Flow

105hp


Hobhole Pumping Station

Hobhole

 

Opened in 1957

 

For pumping information please go to the pump status link.

 

Hobhole Pumping Station Statistics:

No. Of Pumps

Size (Dia)

Type

Power

Total Capacity

Catchment Area

3

88"

Mixed Flow

770hp

1,300 cusecs

84,000ac

4

850mm

Submersible

2200kw

(36.5 cumecs)

(34,000ha)